Excalibur sport

The standard in Sports Medical diagnostic and performance testing.
The Gold Standard in Ergometry: with proven accuracy and reliability, the Excalibur sport is renowned worldwide as “the gold standard in ergometry”. The newly designed and improved Excalibur sport ergometer meets the latest requirements of modern sports medicine and research. Since athletes are becoming more and more powerful and testing more advanced than ever, this ergometer has been developed for extreme workloads up to 2500 watt! The new design ensures maximum stability at these high workloads. Thanks to the increased adjustability, versatile positioning of the test subject has never been better! The function of this product can be enhanced by using it in combination with our Lode Ergometry Manager software.

Extreme workload range of 8 - 2500 watt

The extraordinary workload range of 8-2500 watt is unique in the world! It makes this ergometer extremely suitable for sports medicine
and testing the strongest athletes in the world on their anaerobic power or isokinetic capacity.

Read out of seating position

The Excalibur Sport has a unique read-out of the seating position on the display of the Control Unit.
The display shows saddle height & angle, handlebar position vertical & height.

Various test modes

Besides the hyperbolic (rpm-independent) mode that is used most of the time, the standard control unit offers several other test modes, like the fixed
torque mode and the linear mode.These modes can be used in both manual and terminal mode.

Heavy Duty Design

The Excalibur Sport is designed for heavy duty sports medicine ergometry, without doing any concession on the esthetic,
modern and robust design. In other words: Excalibur Sport: the gold standard in Ergometry!

Easy to clean

The design of the ergometer and the housing material make it very easy to clean.

previous arrow
next arrow
Slider

Extreme low start up load
The extreme low start-up load of 7 watts and the adjustability in small steps of 1 watt make this ergometer perfectly suitable for many different applications. The standard control unit shows multiple ergometry parameters and you can determine your specific default setting and start-up menu.

Small adjustment steps
The workload of the Lode ergometers is adjustable in steps of only 1 watt. Depending on your wishes, the test operator or the test subject can adjust the workload. The steps of 1 watt are possible in the manual mode as well as within protocols.

Compatible with ECG and pulmonary devices
The Lode ergometers have digital interfaces and can be controlled easily by all known stress ECG and pulmonary devices available in the world. This is one of the reasons why the Lode ergometers are very popular worldwide.

Accurate over a long period of time
The Lode ergometers are supplied with an electro-magnetic braking mechanism of Lanooy (eddy current). The biggest advantage of this braking system compared to a friction braking system is the absolute accuracy and the accuracy over time. Moreover, friction braking systems have more wearing parts.

Designed to be sweat-proof
The housing of the ergometer is designed in such way that sweat does not have the chance to drip into the mechanical parts. This ensures a long lifetime and makes the ergometer insensitive for malfunction.

LEM compatible
This product can be used with Lode Ergometry Manager (LEM) software to manage data and to apply specific protocols when a Communication card or Network card is present

Adjustable handlebar Excalibur Sport
The position of the handlebar of Excalibur Sport is completely adjustable in height and length

Adjustable saddle
The position of the saddle of the excalibur sport can be adjusted in height, length and angle to suit all users

Compatible with click pedals
The bicycle ergometer is compatible with most available clickpedals to allow for maximum user flexibility

Instant maximum load
By selecting P-slope max the ergometer immediately reaches maximum power

Minimum load 7 W the minimum load the ergometer can provide
Maximum peak load 2500 W the maximum load the ergometer can provide for a short period of time
Isokinetic workload control control ergometer in isokinetic way
Minimum load increments 1 W the smallest steps with which the load can be added
Maximum continuous load 1500 W the maximum power the ergometer can deliver continuous
Hyperbolic workload control control of workload in hyperbolic way
Linear workload control control ergometer in a linear way
Fixed torque workload control control ergometer in a fixed torque way
Maximum rpm independent constant load 180 rpm rpm as to which constant load can be applied
Minimum rpm independent constant load 25 rpm rpm as from which constant load can be applied
Optional heart rate controlled workload control the device optionally through a set heartrate
Electromagnetic «eddy current» braking system system that very accurately applies a brake to the ergometer
Dynamic calibration continuous calibration during application of workload
Workload accuracy below 100 W 2 W accuracy of the ergometer below 100 Watt load
Workload accuracy from 100 to 1500 W 2% accuracy of the ergometer between 100 and 1500 Watt
Workload accuracy over 1500 W 5% accuracy of the ergometer over 1500 Watt
Toeclips on pedals fixation of the feet on pedals to enable optimal force transition
Q-factor 147 mm Q-factor
Minimum leg length user 725 mm leg length to fit to pedals
Minimum leg length user (incl. adjustable pedals) 650 mm leg length to fit to pedals when adjustable cranks are used (measured inseam)
Vertical seat adjustment maximum 938 seat adjustment maximum height from crank axis to seat top
Vertical seat adjustment minimum 550 seat adjustment minimum height from crank axis to seat top
Horizontal seat adjustment minimum 72 horizontal seat adjustment minimum distance from crank axis to seat midpoint
Horizontal seat adjustment maximum 324 horizontal seat adjustment maximum distance from crank axis to seat midpoint
Seat angle adjustment maximum 10° angle adjustment of the seat bar versus the crankaxis
Allowed user weight 180 kg maximum patient weight
Horizontal handlebar adjustment minimum 229 mm horizontal handlebar adjustment minimum distance from crank axis to center of handlebar mounting point
Horizontal handlebar adjustment maximum 600 mm horizontal handlebar adjustment maximum distance from crank axis to center of handlebar mounting point
Vertical handlebar adjustment minimum 465 mm vertical handlebar adjustment minimum distance from crank axis to center of handlebar mounting point
Vertical handlebar adjustment maximum 855 mm vertical handlebar adjustment maximum distance from crank axis to center of handlebar mounting point
Handlebar adjustment angle 360° angle over which the handlebar can rotate
Readout Distance Readout the distance on control unit
Readout RPM Readout the actual rpm on control unit
Readout Heartrate Readout the actual rpm on control unit
Readout target HR lReadout the actual rpm on control unit
Readout Energy Readout the energy on control unit
Readout Torque Readout torque on control unit
Readout Time Readout time on control unit
Readout Power Readout the actual power on control unit
Set Display Choosing parameters to be shown on the display during the stress test
Set Resistance Possibility to define a specific resistance for each test subject
Set P-Slope Possibility to set the load regulation resistance
Set Mode Possibility to define parameters to be adjusted during the stress test
Manual operation mode Operate manually
Preset protocol operation mode Operate via preset protocols
Analog operation mode Operate analog
Terminal operation mode Operate with an external device
External control unit A control unit is connected with a cable to the ergometer
Selfdesigned protocol operation mode Operate via selfdesigned protocols
Product length 130 cm length of product in cm
Product width 70 cm width of the product in cm
Product height 89 cm height of product
Product weight 100 kg the weight of the product
Power cord length 250 cm length of powercord including plugs
Power cord IEC 60320 C13 with CEE 7/7 plug European power cord and connector standard supplied with produc
Power cord NEMA X NEMA power cord and connector
115 V AC 50/60 Hz (130 VA) operational power
230 V AC 50/60 Hz (130 VA) operational power
IEC 60601-1:2005
The product is IEC 60601-1 3rd edition compliant
ISO 13485:2016 compliant Lode fulfils ISO 13485:2016 requirements
ISO 9001:2015 compliant Lode fulfills ISO 9001: 2015 requirements
Minimum load increments 1 W the smallest steps with which the load can be added
Maximum continuous load 1500 W the maximum power the ergometer can deliver continuous
Hyperbolic workload control control of workload in hyperbolic way
Linear workload control control ergometer in a linear way
Fixed torque workload control control ergometer in a fixed torque way
Maximum rpm independent constant load 180 rpm rpm as to which constant load can be applied
Minimum rpm independent constant load 25 rpm rpm as from which constant load can be applied
Optional heart rate controlled workload control the device optionally through a set heartrate
Electromagnetic «eddy current» braking system system that very accurately applies a brake to the ergometer
Dynamic calibration continuous calibration during application of workload
CE class Im according to MDD93/42/EEC 7 W CE certified
CE class of product with optional SpO2 2500 W CE class of product with optional SpO2
CE class of product with optional BPM CE class of product with optional Blood Pressure Measurement
CB according to IECEE CB 1 W CB certified
Maximum operational temperature 40 °C maximum temperature at which the device will work within specification
Minimum operational temperature 14 °C minimum temperature at which the device will work within specification
Maximum operational air pressure 106 kPa maximum air pressure as from which the product will be operating within specification
Minimum operational air pressure 70 kPa minimum airpressure as from which the product will be operating within specification
Maximum operational non-condensing humidity 90 % maximum non-condensing humidity at which the product will operate within specification
Minimum operational non-condensing humidity 30 % minimum non-condensing humidity at which the product will operate within specification
Maximum storage & transport temperature 70 °C maximum temperature the product may be stored or transported at
Minimum storage & transport temperature -25 °C minimum temperature the product may be stored and transported at
Maximum storage & transport air pressure 106 kPa maximum air pressure the product may be stored and transported at
Minimum air pressure storage & transport 50 kPa minimum air pressure the product may be stored or transported at
Max. humidity storage & transport 95 % max. non-condensing humidity that the product can be stored or transported at
Min. humidity storage & transport 10 % minimum non-condensing humidity that the product can be stored or transport at